Calcolatrice ingegneristica
Capacitor Energy and Peak Current Calculator
How to read the diagram. Closing the switch dumps the stored charge through the load resistor. Peak current is set by V / R at the instant of closure and then decays as e−t/RC, which is the pulse drawn on the right.
Stored energy decides whether a pulse is safe and whether the capacitor survives it. Enter capacitance, voltage and the discharge resistance to get energy, charge and peak current.
ingressi
Risultati
- Energia immagazzinata
- -
- Ricarica
- -
- Corrente di picco
- -
- Tempo costante
- -
La formula
E = ½ × C × V². Charge Q = C × V. Peak discharge current I = V / R at the instant the circuit closes, decaying with τ = R × C.
What the calculator does not include
- Durata dell'impulso. Peak current lasts microseconds in a low-resistance loop. The capacitor must be rated for that dV/dt, not only for the energy.
- Ripetizione. A pulse that is safe once can overheat at 100 Hz. Ask for pulse data on the specific part.
- Dielectric absorption. After discharge the capacitor recovers part of its voltage, which is why bleeder design matters.
Scelta dei componenti
Pulse and PFN duty usually calls for N4700 Class 1 in a radial disc screw-terminal doorknob. Class 2 drift makes those parts a poor fit for repeated pulses.
Send the calculated values and the duty: request a technical quote, risposta entro 6 ore.