Calcolatrice ingegneristica

Cockcroft-Walton Multiplier Calculator

AC dentroVpkC1C3C5C2C4C6D1D2D3D4D5D6+HV2nVpk− return

How to read the diagram. C1, C3 and C5 are the pump capacitors on the AC side; C2, C4 and C6 are the smoothing capacitors; D1 to D6 are the rectifier chain that hands charge from one stage to the next. The DC output is taken across the smoothing column, so three stages give 2 × 3 × Vpk at no load, and n stages give 2 × n × Vpk.

A Cockcroft-Walton multiplier adds the AC peak once per stage, so n stages reach 2 × n × Vpk with nothing connected to the output. As soon as the load draws current, the stage capacitors partly discharge between cycles: the output sags by a voltage drop that grows with the cube of the stage count, and it carries a peak-to-peak ripple. This calculator returns the no-load output, that drop, the ripple, the loaded output and the effective output capacitance, so you can see whether the stage count and capacitance you picked still hold at the current you need.

ingressi

Risultati

Model: full-wave cascade, C = capacitance of one capacitor per stage, f = AC frequency in Hz, I = DC load current.

No-load output
-
Caduta di tensione
-
Ripple (p-p)
-
Output under load
-
Effective output C
-

La formula

No-load V0 = 2 × n × Vpk. Drop ΔV = (I / (f × C)) × (2n³/3 + n²/2 − n/6). Ripple δV = (I / (f × C)) × n(n+1)/2. Output under load = V0 − ΔV. Example: 6 stages, 10 kV peak, 1 nF per stage, 50 kHz and 1 mA gives 120 kV no-load, 3.22 kV drop and 116.8 kV loaded.

What the calculator does not include

Scelta dei componenti

Multiplier capacitors are Class 1 N4700 so the stages divide evenly: radial disc for compact stages, morsetto a vite above 40 kV. Diodes are on the rectifier page.

Send the calculated values and the duty: request a technical quote, risposta entro 6 ore.