Voltage Coefficient (VCR) Error Calculator
Come leggere il diagramma. The top resistor changes value as the voltage across it rises, so the ratio at 20 kV is not the ratio you measured on the bench. The curve is that drift and dR/R is the error the calculator returns.
A thick film resistor is not the same value at 20 kV as on a bench meter. VCR is quoted in ppm per volt; this turns it into the resistance change and the divider error it causes.
ingressi
Risultati
- R1 change
- -
- Ratio at 0 V
- -
- Ratio at working V
- -
- Errore di rapporto
- -
- Output at working V
- -
La formula
ΔR/R = VCR × V / 1,000,000. Divider ratio = (R1 + R2) / R2; recalculate it with the shifted R1 to get the error.
Cosa non include la calcolatrice
- TCR. The resistor also drifts with temperature and the two effects add. A part with −1 ppm/V and 25 ppm/°C can drift more from a 40 °C rise than from full voltage.
- Non-linearity. VCR is not perfectly linear; the quoted figure is typical at rated voltage.
- Self-heating. Current through R1 raises its temperature, which shifts the value again.